Design and Implementation of Data Collection & Analysis Tool for Healthcare Parameter Monitoring using Inverse Low Pass Filter

Authors

  • S. K. Chaurasia Indira Gandhi Delhi Technical University for Women image/svg+xml
  • S.R.N Reddy Indira Gandhi Delhi Technical University for Women image/svg+xml

DOI:

https://doi.org/10.4108/eai.30-10-2018.160460

Keywords:

Activity Detection, Context Detection, Gravity Removal, Inverse Low Pass Filters, Machine Learning

Abstract

BACKGROUND: Health of an individual can be determined by monitoring his daily activities. Human Activity Recognition (HAR) is a process, used to record these activities. The first step of HAR involves collection of Data from various Sensors, which is challenging due to the requirement of interfacing of hardware Sensors. Researchers either do hardware interfacing themselves or just analyse already available dataset. In the literature, many measures are proposed to calculate the human activities by using the Accelerometer data. But, different activities recorded by Accelerometer are not accurate due to presence of gravity component. Also there is requirement of identification of appropriate Machine learning algorithm for HAR.

OBJECTIVE: To facilitate the researchers in hassle free data collection for monitoring HAR and finding optimal cutoff frequency to remove gravity component present in accelerometer data. Also detecting suitable machine learning model for HAR.

METHODS: An application has been developed using Inverse low pass filter with an optimal threshold value to compute cut-off frequency for the removal of gravity component from accelerometer data. 8 different machine learning models are trained and tested for examining suitability of models on the collected data at server. Accuracy and execution time are considered as validation parameters.

RESULTS: Gravity Component is removed and data gathered by using 0.6 alpha is providing 0.05 mean acceleration in static state. Among Various ML models k Nearest Neighbor is providing 93.17 percent of accuracy with 0.187486 sec of execution time.

CONCLUSION: Removal of Gravity component is optimised by our method and out of various ML model kNN is identified as suitable model for HAR.

Downloads

Download data is not yet available.

Downloads

Published

30-10-2018

How to Cite

1.
Chaurasia SK, Reddy S. Design and Implementation of Data Collection & Analysis Tool for Healthcare Parameter Monitoring using Inverse Low Pass Filter. EAI Endorsed Trans Perv Health Tech [Internet]. 2018 Oct. 30 [cited 2024 Nov. 23];4(16):e5. Available from: https://publications.eai.eu/index.php/phat/article/view/1283