ICT-Supported Scenario-Aware Adaptive Setting Method for Line Current Protection in Distribution Networks with High Proportion of Distributed Generation

Authors

  • Dongfang Wang Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China
  • Xudong Ouyang Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China
  • Xudong Song Electric Power Research Institute of Guangdong Power Grid Co., Ltd., China
  • Yongjun Liu Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China
  • Shuiyuan Liu Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China
  • Yanpeng Feng Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China
  • Yangyang Dai Heyuan Power Supply Bureau, Guangdong Power Grid Co., Ltd., China

DOI:

https://doi.org/10.4108/ew.14213

Keywords:

high proportion of distributed generation, scenario self-adaptation, setting value switching, current protection

Abstract

INTRODUCTION: With the large-scale integration of distributed generators (DGs), distribution networks are gradually evolving into multi-source power supply systems. Although high-penetration DG integration improves system operational flexibility and power supply reliability, it changes fault current distribution characteristics and weakens the adaptability of conventional fixed-setting overcurrent protection. Under high DG penetration, wide-range DG output fluctuations and load demand variations may lead to protection miscoordination, maloperation, or failure to operate. OBJECTIVES: To address these challenges, this paper aims to develop an ICT-supported scenario-aware adaptive setting method for overcurrent protection in distribution networks with high DG penetration, so as to improve the adaptability, sensitivity, and reliability of line current protection under varying operating conditions. METHODS: The proposed method classifies operating states into typical scenarios according to load demand, DG output, and network topology. Refined protection settings are calculated offline for each scenario by considering the infeed and outfeed effects of DGs. Meanwhile, an information and communication technology (ICT) architecture composed of distribution terminals, intelligent electronic devices, communication networks, and edge computing units is introduced to collect real-time DG output, feeder current, switch status, and topology information. Based on these data, online operating scenario identification and adaptive switching of protection settings are realized. RESULTS: Simulation results show that the proposed method can adapt to different operating scenarios, including a low-load scenario with zero DG output, a high-load scenario, and a high-DG-output scenario with a load of 8 MW. For a fault at point k1, when the system switches from Scenario 1 to Scenario 3, the fault current measured by QF2 decreases to 1.93 kA, which is lower than the original Stage II protection setting of 1.98 kA under Scenario 1 and may lead to protection failure. After applying the proposed method, the Stage II setting of QF2 is adjusted to 1.39 kA, while the protection sensitivity coefficient remains greater than 1.3. In addition, when the load increases from 5 MW to 10 MW, the Stage III setting of QF21 is adjusted from 0.11 kA to 0.23 kA, thereby avoiding the risk of maloperation under heavy-load conditions. CONCLUSION: The proposed ICT-supported scenario-aware adaptive setting method can effectively respond to changes in DG output, load demand, and network topology. By enabling scenario-based setting calculation and online adaptive switching, the method improves the adaptability and reliability of overcurrent protection in active distribution networks with high DG penetration.

Downloads

Download data is not yet available.

References

[1] National Energy Administration. Notice on Issuing the "14th Five-Year Plan for the Modern Energy System": Development and Reform Commission Energy [2022] No. 210 [EB/OL]. (2022-01-29) [2023-03-10]. Beijing: National Energy Administration.

[2] Xu Bingyin. Modern Relay Protection Technology for Distribution Networks and Its Development. Power Supply and Utilization, 2024, 41(08): 65-74 + 87.

[3] Yuan Zhaoxiang, Zhang Yi, Nie Ming, et al. Adaptive Analysis of 10 kV Distribution Network Protection with Distributed New Energy Access. Electric Power Construction, 2024, 45(02): 49-57.

[4] Meskin M, Domijan A, Grinberg I. Impact of distributed generation on the protection systems of distribution networks: analysis and remedies–review paper[J]. IET Generation, Transmission & Distribution, 2020, 14(24): 5944-5960.

[5] Cao Jinming, Fan Kaijun, Xu Bingyin, et al. Applicability analysis of three-stage current protection for high-proportion inverter distributed Power distribution Network based on capacity boundary value. Power Grid Technology, 2019,48(08):3438-3448.

[6] WANG Bao, YA Qiong, CHEN Hao, et al. Overview study on improving protection methods of distribution network with distributed generation. Power System Protection and Control, 2017, 45(12): 146-154.

[7] Gao Shengkai, Cao Wei, Zhang Xuhang, et al. An Improved Adaptive over current Protection Method for Distribution Network. Power System Protection and Control, 2019, 49(7): f110-119.

[8] Quan Lei, Zhan Hongxia, Zhang Yong, et al. Adaptive current-main protection scheme of distribution network considering multi-DG access. Intelligent Electric Power, 21, 49(8):63-69.

[9] Wu D, Kalathil D, Begovic MM, et al. Deep reinforcement learning-based robust protection in DER-rich distribution grids. IEEE Open Access Journal of Power and Energy, 2022, 9: 537-548.

[10] Yuan Zhiyong, Xu Quan, Xu Gang, et al. Current protection optimization Scheme of distribution network with large capacity Distributed Power Access. Power Grid Technology, 2021,45(05):1862-1869.

[11] ZHANG Tianyi, LIANG Zhijian, LIU Bin. Research on Adaptive Protection for Distribution Networks with Multiple Distributed Generations. Journal of Guangxi University (Natural Science Edition), 2023, 48(1): 122-131.

[12] Fang Yuchen, Wang Bin, Zhang Liangli, et al. Adaptive inverse time protection with distributed Power output. Journal of Electric Power Systems and Automation, 2019, 35 (10): 9-17.

[13] Wei Mingjie, Wang Congbo, Yu Yue, et al. Distribution network multi-level protection optimization scheme for high proportion distributed photovoltaic access. Automation of Electric Power Systems, 2023,47(22):55-65.

[14] Xu Bingyin. Relay Protection and Automation of Distribution Network [M]. Beijing: China Power Press, 2017.

[15] General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of China. Technical requirements for grid-connected distributed power supply: GB/T 33593-2017 [S]. Beijing: Standards Press of China, 2017.

[16] Luo Guomin, Zhao Yiwei, Wu Mengyu, et al. Improved adaptive current protection method for distribution network adapting to high proportion of new energy access. Power supply, 2024, 9 (09): 12-23.

[17] Zhu L, Yang X, Wang X, et al. A grid-based scenario delineation method for distribution networks based on fuzzy comprehensive evaluation and SNN-DPC clustering. Processes, 2025, 13(9): 2923-2923.

[18] Mahdavi M, Schmitt K E K, Jurado F. Robust distribution network reconfiguration in the presence of distributed generation under uncertainty in demand and load variations[J]. IEEE Transactions on Power Delivery, 2023, 38(5): 3480-3495.

[19] YAN Yulu, CHENG Yu, CHEN Xi. Distribution network topology and coordinated planning of storage and load resources adapted to photovoltaic high penetration access. Guangdong Electric Power, 2024, 37(12): 50-60.

[20] Li Y, Wan C, Cao Z, et al. Data-driven nonparametric probabilistic optimal power flow: An integrated probabilistic forecasting and analysis methodology[J]. IEEE Transactions on Power Systems, 2022, 38(6): 5820-5833.

[21] Liu ZL, Wang Chengshan, Li Peng, et al. Distribution network-state estimation and application of multi-source Measurement Data Fusion. Proceedings of the CSEE, 2020, 41(8): 2605-2614.

[22] Li P, Zu W J, Liu Y X, et al. Distribution Network State Estimation Method Based on Incomplete Measurement Data. China Electric Power, 2025, 58(05): 1-10.

[23] Wang Zonghui, Chen Yu, Xu Bingyin, et al. Topology identification of distributed feeder automation based on logical nodes[J]. Automation of Electric Power Systems, 2020, 44(12): 124-130.

Downloads

Published

16-09-2026

How to Cite

1.
Wang D, Ouyang X, Song X, Liu Y, Liu S, Feng Y, et al. ICT-Supported Scenario-Aware Adaptive Setting Method for Line Current Protection in Distribution Networks with High Proportion of Distributed Generation. EAI Endorsed Trans Energy Web [Internet]. 2026 Sep. 16 [cited 2026 Sep. 16];13. Available from: https://publications.eai.eu/index.php/ew/article/view/14213